You could also have an air leak around the vent itself between the vent and drywall.
Ceiling condensation leak from hvac attic.
Usually the leak happens where the vent boot attaches to the duct.
Condensation on your ceiling occurs when the attic space above is poorly ventilated and insulated.
Next take a look at your attic.
How to prevent condensation in ceiling vents.
If you have taken the proper steps to remove excess humid air from your home and you re still having condensation issues it might be time to check the attic insulation.
Water builds up in the ceiling and eventually there will be a drip if the homeowner is lucky.
Over time algae can grow inside of this drain line causing backups or clogs.
Water through your ceiling.
Finally and most importantly condensation on ductwork can then drip off of your ducts and feed mold growth.
If no drip then eventually the entire ceiling will fall.
When the cool air from your living space rises due to humidity in your home often from cooking bathing or drying clothes it comes in contact with the warm surface of the ceiling and.
A wet condensate drip pan in a hot attic creates a favorable environment for algae to thrive.
Find and seal the leak.
Insulation is responsible for keeping warm air inside your living space and out of the attic where it can lead to condensation.
If the problem vent is easy to access from your.
So what is causing the water leak.
Take care of your attic hvac air ducts too.
If water is dripping from your ceiling and your furnace and or air handler is located in the attic the most likely cause is a clogged condensate drain line.
Second when water condenses and drips off of your ductwork it can cause your ceiling to leak which can rot drywall and cause your ceiling to collapse over time not to mention it looks horrible.
Condensation dripping from a ceiling vent can have detrimental effects on the ceiling material surrounding the vent as well as carpeting and.
Applying mastic gum to the duct joints and adding an r6 layer of insulation around your sheet metal ducts goes a long way toward protecting your attic and ceiling.
Inspect your attic insulation.
This traps heat in the attic which then warms the ceilings.
Unchecked algae growth may eventually infiltrate the condensate drain.
If not properly sealed the cold air leaks out meets up with the warm attic air and creates condensation.
In the attic i always recommend a float switch installed in the secondary air conditioning condensation drain pan.